extended life, especially when in coastal areas. For all models, we highly recommend that exterior fittings are cleaned once per year with fresh water and oiled
             or waxed to give longer service. Lenses and glasses also benefit from cleaning but take care with polycarbonate or acrylic as these materials can easily scratch
             if any abrasive cloth is used.
             3.  IP RATINGS. All exterior fittings have an IP (Ingress Protection) rating which is a declaration of how much protection any product has against the ingress
             of both water and dust / particles. The minimum rating for an outdoor luminaire exposed to rain should be IP23 and the maximum can be up to IP68 (this
             can vary in different countries) which means the fitting is submersible. Most of our fittings are IP44 or greater and some of the Landscape models are up to
             IP67 meaning they can be covered by water up to a depth of 150mm, such as in-ground lights. See table below for full classifications. Typically, the higher the
             numbers, the higher the performance.

             IP RATINGS
             1st   Short Description                2nd  Short Description
             Digit (Protection against ingress of solid bodies)  Digit (Protection against ingress of moisture)

               0  Non-Protected                      0  Non-protected
               1  Protected against solid objects greater than 50mm dia.  1  Protected against dripping water falling vertically greater than 50mm diameter
               2  Protected against solid objects greater than 12mm dia.  2  Protected against dripping water when the Luminaire is tilted up to 15° from its normal position
               3  Protected against solid objects greater than 2.5mm dia.  3  Protected against spraying water falling on the Luminaire at any angle up to 60° from the vertical
               4  Protected against solid objects greater than 1mm dia.  4  Protected against splashing water from any angle
               5  Dust-protected                     5  Protected against water jets from any direction
               6  Dust-tight                         6  Protected against powerful water jets
                                                     7  Protected against immersion in water under defined conditions
                                                     8  Protected against continuous submersion under manufacturers specified conditions

                  Example IP65 Dust-tight and protected against water jets from any direction.



             COMPLIANCE/APPROVALS
             All products within this catalogue conform with the European Union Low Voltage Directive, BS EN 60598-1:2008, the product standard for luminaires
             recognised across Europe and all fittings are CE marked. Every luminaire is individually tested by Elstead Lighting to ensure that the product is electrically
             sound and meets the company’s quality standards. A unique test / batch number is then applied to the fitting. Please contact us for further details or advise
             us of your local needs.
             We are manufacturing members of the UK Lighting Industry Association and conform to all aspects of the Lighting Industry Association Code of Practice
             for luminaire production.


             ENERGY RATINGS FOR LUMINAIRES
             Please see the relevant energy rating label for the corresponding lamp holder type. Please note that, with the very large number of lamp options available in the
             market, it is impossible for our luminaires to accurately reflect all choices. But all lamps able to be bought in the market should have their own dedicated energy
             rating performance clearly stated on their packaging.




                                                                      LIGHTING

                    This luminaire is         This luminaire            This luminaire contains
                    compatible with bulbs     contains built-in         built-in LED lamps and
                    of the energy classes:    LED lamps.                has sockets for bulbs of
                                                                        the energy classes:
               A ++                      A ++       L              A ++     L
               A +                       A +        E              A +      E
               A                         A          D              A        D
               B                         B                         B
               C                         C                         C
               D                         D                         D
               E                         E                         E

                                        The lamps cannot be changed    The LED lamps cannot be
                                        in the luminaire.         changed in the luminaire.
              874/2012                  874/2012                  874/2012

            All luminaires with replaceable lamps.  Dedicated LED fittings.  Some of our luminaires combine
             Incandescent, fluorescent or LED.                  built-in LED with replaceable lamps.




                                                                                               ELSTEADLIGHTING.COM  213
   208   209   210   211   212   213   214   215   216